The Banlaw Automatic Fuel Filling System uses fuel tank pressure as the signal to stop the refueling operation.

The nozzle constantly senses pressure at its outlet (inlet to the tank). When the fuel level reaches the vent valve the outlet from the tank is closed and the tank pressure begins to build. When the pressure reaches the "set" pressure for the nozzle used the nozzle will shutoff.

The system is totally independent from the loading facility except for the fuel nozzle connection interface. The system schematically shown to the right requires that a receiver and vent be installed in the fuel tank and a connecting nozzle is supplied from the loading rack. A small bleed hole in the vent allows the tank pressure to return to normal within a few seconds. This system utilizes a type of nozzle/receiver that has wide acceptance within the industry. The Megatrol nozzles/receivers are fully interchangeable with the existing Wiggins and similar units. See the table of interchangeable items later in this bulletin.

The BAM800 Nozzle is capable of delivering flow rates from 47-210 gpm. For higher flow rates (up to 265 gpm) ask about the higher flow rate 2" nozzle BAM1000M.

FEATURES
• Environmentally friendly - no spillage.
• Filling point location unrestricted.
• No foaming as in splash filling.
• Higher refueling rate than splash filling - up to 210 gpm.
• Nozzles, receivers & vents interchangeable with Wiggins and other equipment.
 


Banlaw automatic nozzle with a full 2” bore is fully interchangeable with the appropriate Wiggins and other nozzles. The BAM800 Nozzle is capable of delivering flow rates from 47-210 gpm

MODEL BAM800 NOZZLE

Various vents with different lengths, outlet and mounting configurations are available. ¾” breather pipe which will allow up to 210 GPM fuel filling, splash tube, 2” NPT threads.

MODEL AUS25 VENT

Receiver is made of steel and with open internal configuration allows for maximum flow.

Polyurethane Dust Caps are available and highly recommended to keep the interface between the Nozzle and Receiver clear of debris.

MODEL AUS23 RECEIVER

To adapt BAM800 Nozzles when “splash” filling is required on a vehicle not equipped with a Receiver. Use AUS6A for straight configuration and AUS6B for 90° as shown.

AUS6B SPOUT


For recessed mounting of the fuel receiver.

MODEL AUS24A007 FLUSH-WELD SHELL

 